Home Login Contact Safety Site  People 
Chemistry @ Queen's Undergraduate Students Graduate Students Research Alumni People
Publications
 

 

 

Diane BeaucheminPublications

Dr. Beauchemin's Research Page

Axelle Leufroy, Laurent Noël, Diane Beauchemin and Thierry Guérin, "Use of a continuous leaching method to assess the oral bioaccessibility of trace elements in seafood", Food Chem., in press (accepted March 12, 2012).
 
Axelle Leufroy, Laurent Noël, Diane Beauchemin and Thierry Guérin “Bioaccessibility of total arsenic and arsenic species in seafood as determined by a continuous online leaching method”, Anal. Bioanal. Chem. in press (DOI 10.1007/s00216-012-5774-4).
 
Nolan S. Horner and Diane Beauchemin, “A simple method using on-line continuous leaching and ion exchange chromatography coupled to inductively coupled plasma mass spectrometry for the speciation analysis of bio-accessible arsenic in rice”, Anal. Chim. Acta 717 (2012) 1-6. Featured article on the cover of the issue.
 
Alemayehu Asfaw and Diane Beauchemin, “Combination of a multimode sample introduction system with a pre-evaporation tube to improve multi-element analysis by ICP-OES”, J. Anal. At. Spectrom. 27 (2012) 80-91.
 
Liyan Xing and Diane Beauchemin, "Kinetics study of the reduction of Cr(VI) in natural water with ion exchange chromatography coupled to inductively coupled plasma mass spectrometry ", J. Anal. At. Spectrom. 26 (2011) 2006-2011.
 
Christian Agatemor and Diane Beauchemin, “Towards the Reduction of Matrix Effects in Inductively Coupled Plasma Mass Spectrometry: the Use of Argon-nitrogen Mixed-gas Plasma”, Spectrochim. Acta Part B 66 (2011) 1-11.
 
Christian Agatemor and Diane Beauchemin, “Matrix Effects in Inductively Coupled Plasma Mass Spectrometry: a Review”, Anal. Chim. Acta, 706 (2011) 66-83.

Axelle Leufroy, Laurent Noël, Vincent Dufailly, Diane Beauchemin and Thierry Guérin, "Determination of seven arsenic species in seafood by ion exchange chromatography coupled to inductively coupled plasma - mass spectrometry following microwave assisted extraction: Method validation and occurrence data”, Talanta 83 (2011) 770-779.
 
Liyan Xing and Diane Beauchemin, "Chromium speciation at trace level using hyphenated ion exchange chromatography and inductively coupled plasma mass spectrometry with collision/reaction interface", J. Anal. At. Spectrom. 25 (2010) 1046-1055.
 
Alemayehu Asfaw and Diane Beauchemin, "Improvement of the Capabilities of Inductively Coupled Plasma Optical Emission Spectrometry by Replacing the Desolvation System of an Ultrasonic Nebulization System with a Pre-evaporation Tube", Spectrochim. Acta Part B 65 (2010) 376-384.
 
Diane Beauchemin, "Environmental Analysis by Inductively Coupled Plasma Mass Spectrometry", Mass Spectrom. Rev., 29 (2010) 560-592.

Diane Beauchemin, "Inductively Coupled Plasma Mass Spectrometry", Anal. Chem., 82 (2010) 4786-4810.

Alemayehu Asfaw and Diane Beauchemin, "Sample Introduction: Gas Chromatography" in Chapter 1 on "Plasma Ionization: ICP" of Volume 5 of the "Encyclopedia of Mass Spectrometry, Eds. M. L. Gross and R. M. Caprioli, Elsevier, London, 2010, 58-73.
 
Liyan Xing and Diane Beauchemin, "Sample Introduction: Liquid Chromatography" in Chapter 1 on "Plasma Ionization: ICP" of Volume 5 of the "Encyclopedia of Mass Spectrometry, Eds. M. L. Gross and R. M. Caprioli, Elsevier, London, 2010, 73-81.
 
Diane Beauchemin, "Interferences: Non-spectroscopic Interferences" in Chapter 1 on "Plasma Ionization: ICP" of Volume 5 of the "Encyclopedia of Mass Spectrometry, Eds. M. L. Gross and R. M. Caprioli, Elsevier, London, 2010, 150-158.
 
Diane Beauchemin, " Application of Inductively Coupled Plasma Mass Spectrometry to Environmental Analysis" in Chapter 1 on "Plasma Ionization: ICP" of Volume 5 of the "Encyclopedia of Mass Spectrometry, Eds. M. L. Gross and R. M. Caprioli, Elsevier, London, 2010, 158-172.

Matheson M. Fraser and Diane Beauchemin, "Evidence supporting the occurrence of Coulomb fission during conventional sample introduction in inductively coupled plasma mass spectrometry ", J. Anal. At. Spectrom. 24 (2009) 469-475.
 
Liyan Xing and Diane Beauchemin, "Determination of stability constants of metal complexes with IC-ICP-MS", J. Anal. At. Spectrom. 24 (2009) 336-339.
 
Vincent Dufailly, Thierry Guérin, Laurent Noël, Jean-Marc Frémy and Diane Beauchemin, "A simple method for the speciation analysis of bio-accessible arsenic in seafood using on-line continuous leaching and ion exchange chromatography coupled to inductively coupled plasma mass spectrometry", J. Anal. At. Spectrom., 23 (2008) 1263-1268.
 
A. J. Fitzpatrick, T. K. Kyser, D. Chipley, and D. Beauchemin, Fabrication of solid calibration standards by a sol-gel process and use in laser ablation ICPMS, J. Anal. At. Spectrom. 23 (2008) 244–248.
 
Diane Beauchemin, "Inductively Coupled Plasma Mass Spectrometry", Anal. Chem., 80 (2008), 4455–4486.

Vincent Dufailly, Laurent Noël, Jean-Marc Frémy, Diane Beauchemin and Thierry Guérin, "Optimisation by experimental design of an HPLC/ICP-MS speciation method for arsenic in fish products following microwave assisted extraction", J. Anal. At. Spectrom. 22 (2007) 1168-1173.
 
Milithza Silva, Kurt Kyser and Diane Beauchemin, "Microwave-assisted continuous leaching on-line with inductively coupled plasma mass spectrometry for exploration and environmental geochemistry", Journal of Geochemical Exploration, 94 (2007) 30-42.

 
Milithza Silva, Kurt Kyser and Diane Beauchemin, "Enhanced flow injection leaching of rocks by focused microwave heating with in-line monitoring of released elements by inductively coupled plasma mass spectrometry", Anal. Chim. Acta. 584 (2) (2007) 447-454.

Diane Beauchemin, Diane Beauchemin, "Environmental Analysis by Inductively Coupled Plasma Mass Spectrometry", Mass Spectrom. Rev., Published Online: Aug 31 2009 2:21PM, DOI: 10.1002/mas.20257

Matheson M. Fraser and Diane Beauchemin, "Evidence supporting the occurrence of Coulomb fission during conventional sample introduction in inductively coupled plasma mass spectrometry ", J. Anal. At. Spectrom. 24 (2009) 469-475.

Liyan Xing and Diane Beauchemin, "Determination of stability constants of metal complexes with IC-ICP-MS", J. Anal. At. Spectrom. 24 (2009) 336-339.

Vincent Dufailly, Thierry Guérin, Laurent Noël, Jean-Marc Frémy and Diane Beauchemin, "A simple method for the speciation analysis of bio-accessible arsenic in seafood using on-line continuous leaching and ion exchange chromatography coupled to inductively coupled plasma mass spectrometry", J. Anal. At. Spectrom., 23 (2008) 1263-1268.

A. J. Fitzpatrick, T. K. Kyser, D. Chipley, and D. Beauchemin, Fabrication of solid calibration standards by a sol-gel process and use in laser ablation ICPMS, J. Anal. At. Spectrom., 23 (2008) 244248.

Diane Beauchemin, "Inductively Coupled Plasma Mass Spectrometry", Anal. Chem., 80 (2008), 4455-4486.

Vincent Dufailly, Laurent Noël, Jean-Marc Frémy, Diane Beauchemin and Thierry Guérin, "Optimisation by experimental design of an HPLC/ICP-MS speciation method for arsenic in fish products following microwave assisted extraction", J. Anal. At. Spectrom., 22 (2007) 1168-1173.

Milithza Silva, Kurt Kyser and Diane Beauchemin, "Microwave-assisted continuous leaching on-line with inductively coupled plasma mass spectrometry for exploration and environmental geochemistry", Journal of Geochemical Exploration, 94 (2007) 30-42.

Milithza Silva, Kurt Kyser and Diane Beauchemin,"Enhanced flow injection leaching of rocks by focused microwave heating with in-line monitoring of released elements by inductively coupled plasma mass spectrometry", Anal. Chim. Acta., 584 (2) (2007) 447-454.


Shulan Liu and Diane Beauchemin, "Effect of concomitant analytes on As signal during pre-evaporation of the solvent prior to introduction into inductively coupled plasma mass spectrometry", Spectrochim. Acta Part B, 61, 965-970 (2006).

Chaoyang Huang and Diane Beauchemin, "Simultaneous Determination of Two Conditional Stability Constants by IC-ICP-MS", J. Anal. At. Spectrom., 21, 1419-1422 (2006).

Shulan Liu and Diane Beauchemin, "Effect of methanol and sodium dodecylsulfate on radial profiles of ion abundance in inductively coupled plasma mass spectrometry", Spectrochim. Acta Part B, 61, 319-325 (2006).

Diane Beauchemin, "Inductively Coupled Plasma Mass Spectrometry", Anal. Chem., 78, 4111-4136 (2006).

Chaoyang Huang and Diane Beauchemin, "A Simple Method Based on IC-ICPMS to Determine Conditional Stability Constants", J. Anal. At. Spectrom., 21,317-320 (2006).

Shulan Liu and Diane Beauchemin, "Fundamental studies on the effect of pre-evaporation in inductively coupled plasma mass spectrometry", Spectrochim. Acta Part B, 61, 157-163 (2006)

Mingyan Chu and Diane Beauchemin, "Méthode améliorée pour évaluer la bio-accessibilité maximale des éléments dans les aliments solides par spectrométrie de masse à plasma à couplage inductif", Can. J. Anal. Sci. Spectrosc., 51, 323-329
(2005).

W.R. MacFarlane, T.K. Kyser, D. Chipley, D. Beauchemin and C. Oates, "Continuous leach inductively coupled plasma mass spectrometry: applications for exploration and environmental geochemistry", Geochemistry: Exploration, Environment, Analysis, 5, 123–134 (2005).

 Mathieu L. Viger, Jean-Francois Y. Gravel, Danny Brouard, Diane Beauchemin et Denis Boudreau, "Use of Sol-Gels as Solid Matrixes for Trace Analysis by UV Laser Ablation and Laser-Enhanced Ionization Detection", Anal. Chem., 77, 706-710 (2005).

Diane Beauchemin, "Determination of the most precise isotope ratios from transient signals in inductively coupled plasma mass spectrometry", Can. J. Anal. Sci. Spectrosc., 49, 436-443 (2004).

Mingyan Chu and Diane Beauchemin, "Simple method to assess the maximum bio-accessibility of elements from food using flow injection and inductively coupled plasma mass spectrometry", J. Anal. At. Spectrom.,19, 1213–1216 (2004).

D. Chipley, T.K. Kyser, Diane Beauchemin and Bill MacFarlane
, On-Line Continuous Leach Analysis of Soils by HR-ICP-MS, Can. J. Anal. Sci. Spectrosc., 48, 269-276 (2003).

Alison E. Holliday and Diane Beauchemin, Spatial profiling of analyte
signal intensities in ICP-MS
, (invited refereed review) Spectrochim. Acta, in press (accepted December 22, 2003).

Holliday, A.E.; Beauchemin, D., Preliminary investigation of direct sea-water analysis by inductively coupled plasma mass spectrometry using a mixed-gas plasma, flow injection and external calibration. Journal of Analytical Atomic Spectrometry 18, 1109-1112 (2003).
 

Huang, C.Y.; Beauchemin, D., Direct multielemental analysis of human serum by ICP-MS with on-line standard addition using flow injection. Journal of Analytical Atomic Spectrometry 18, 951-952 (2003).
 

Holliday, A.E.; Beauchemin, D., Spatial profiling of ion distributions in a nitrogen-argon plasma in inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 18, 289-295 (2003).
 

Holliday, A.E.; Beauchemin, D., Radial profiles of ion abundance in cold plasmas and mixed-gas plasmas in inductively coupled plasma mass spectrometry. Canadian Journal of Analytical Sciences and Spectroscopy 47, 91-97 (2002).
 

Beauchemin, D.; Kyser, K.; Chipley, D., Inductively coupled plasma mass spectrometry with on-line leaching: A method to assess the mobility and fractionation of elements. Analytical Chemistry 74, 3924-3928 (2002).
 

Beauchemin, D., Inductively coupled plasma mass spectrometry. Analytical Chemistry 74, 2873-2893 (2002).
 

Fraser, M.M.; Beauchemin, D., Effect of concomitant elements on the distribution of ions in inductively coupled plasma mass spectrometry - part 2: polyatomic ions. Spectrochimica Acta Part B- Atomic Spectroscopy 56, 2479-2495 (2001).
 

Chen, H.H.; Beauchemin, D., Determination of trace metals in saline water using flow injection on-line precipitation coupled with inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 16, 1356-1363 (2001).
 

Xiao, G.; Beauchemin, D., Mixed Ar-N-2 plasmas: Simple antidotes to matrix effects in ICP-MS. Canadian Journal of Analytical Sciences and Spectroscopy 46, 28-37 (2001).
 

Chen, H.H.; Beauchemin, D., Determination of copper in saline water using flow injection on line precipitation coupled with inductively coupled plasma mass spectrometry. Canadian Journal of Analytical Sciences and Spectroscopy 45, 84-89 (2000).
 

Fraser, M.M.; Beauchemin, D., Effect of concomitant elements on the distribution of ions in inductively coupled plasma-mass spectroscopy. Part 1. Elemental ions. Spectrochimica Acta Part B- Atomic Spectroscopy 55, 1705-1731 (2000).
 

Persaud, A.T.; Beauchemin, D.; Jamieson, N.E.; McLean, R.J.C., Partial leaching as an aid to slurry nebulization for the analysis of soils by ICP-MS with flow injection and mixed-gas plasmas. Canadian Journal of Chemistry 77, 409-415 (1999).
 

Beauchemin, D.; Specht, A.A., Analysis of river water by ICP-MS with on-line preconcentration using flow injection. Canadian Journal of Analytical Sciences and Spectroscopy 43, 43-48 (1998).
 

Beauchemin, D.; Kisilevsky, R., A method based on ICP-MS for the analysis of Alzheimer's amyloid plaques. Analytical Chemistry 70, 1026-1029 (1998).
 

Specht, A.A.; Beauchemin, D., Automated on-line isotope dilution analysis with ICP-MS using sandwich flow injection. Analytical Chemistry 70, 1036-1040 (1998).
 

Beauchemin, D., Hydride generation interface for the determination of inorganic arsenic and organoarsenic by inductively coupled plasma mass spectrometry using open-focused microwave digestion to enhance the pre-reduction process. Journal of Analytical Atomic Spectrometry 13, 1-5 (1998).
 

Beauchemin, D.; Specht, A.A., On-line isotope dilution analysis with ICPMS using reverse flow injection. Analytical Chemistry 69, 3183-3187 (1997).